Programming Example
To program the installation example given in Section 2 some changes need
to be made to the factory default settings. For the example we will assume
that the:
Entry time must be 30 seconds
Exit time must be 45 seconds.
Entry Exit zone and back door should chime.
System should rearm three times.
Key in: Result
1. 0 + R + 7890 The panel enters programming mode and
all LEDs (except Power) flash in unison.
2. 10 + R + 6 + R Zone 6 is by passed during Part Set.
3. 11 + R + 72 + R Entry exit zone and zone 2 are chime
zones.
4. 40 + R + 4 + R Rearm three times.
5. 43 + R + 3 + R Entry time 30 seconds.
6. 44 + R + 4 + R Exit time 45 seconds.
7. 52 + R + 1 + R Zone 1 is Entry/Exit Zone in Part Set.
8. 99 + R Leave programming mode.
If you wish to make zone 6 a PA zone, then you could add the step:
7a. 50 + R + 1 + R Zone 6 is a PA zone.