Installation Menvier40/100
Page 12
carrier into the holes provided, see Figures
15 to 17.
Figure
Fit Securing Screw
When the PCB is in place, connect the wires
from the transformer to the 20Vac
connector on the PCB (11 in Figure 3).
Installing the Lid/Back Tamper
Figure
Lid/Back Tamper
Fit combined lid/back tamper bracket and
switch (provided). Ensure that the switch is
oriented as shown in Figure 18.
Connect the lead from the switch to the
back tamper connector on the PCB (see 2 in
Figure 3).
Note that to be approved at Security Grade
3 you must fit the lid/back tamper.