Omit Circuits
Occasionallyitmaybenecessarytoomitdetectioncircuitswhensettingorpartsettingthe
system.Thisallows theuseraccess tothe omittedarea(s)when thesystem issetor partset.
It is also possible to omit 24hr or Auxiliary circuits so that access to these areas can be
obtained when the system is unset.
Only detection circuits that have been programmed by
your alarm company as “Omit” can be selected when
using this option.
1. From the unset (open) mode enter your passcode
and press [ENT] to select user menu 1.
2. Whilstuser menu1 isselected. Press[7] toselect the
omit circuits option.
3. Select the circuit you require to omit by either
entering the circuit number or by using the [A] and
[C] keystoscrollupanddownthroughthecircuits.
4. When the requiredcircuit number is displayed press
the [B] key to alternate between “Armed” and
“Omitted”. If a low tone is heard when pressing the
[B] key the selected circuit cannot be omitted.
5. When the display shows the required setting for the
selected circuit, press the [ENT] key to accept. A
rising multi-tone will be heard and the display will
show the next available circuit.
6. If required repeat from step (3) for other circuits,
When you have selected all the required circuits,
press the [ESC] key.
a) If you have selected 24hr circuits, the system
will automatically return to the unset mode
and the display will indicate that circuits are
isolated.
b) If you have only selected night circuits, the
system will return to user menu 1. From user
menu 1 you must press [0] to full set, [A], [B]
or [C] for part set.
w
Ifyou haveselected a nightcircuit tobe omitted, youmust performa full or
part set whilst the user menu is selected. If you return to system open all
selected circuits will be cancelled.
18
User menu 1
Select Option :-
User menu 1
Select Option :-
SYSTEM OPEN
17:30 01 JAN
Please Exit Now.
Time Left > 9999
Omit Circuits
Enter CCT No.>-
Office Detector
CCT 03 Armed
Office Detector
CCT 03 Omitted
Store Room PIR
CCT 04 Armed
CCTS ISOLATED
09:45 01 JAN
ENT
ESC
7
1
2
3
4
5
6
a
b
0
A
3 C
OR
/
B
0 A B C
? ? ? ?
ENT
+
LCD Remote
NOTES