4-26 SPARC Enterprise Mx000 Servers XSCF User’s Guide • December 2010
4.7 Changing the Time
The time of the server is based on the XSCF time. Time can be displayed or set to local time
or UTC. For details on displaying or setting the system time, see Chapter 2.
4.8 Switching the XSCF Unit
In some cases, such as when an error occurs in the LAN route of the XSCF Unit on the
active side in a system in which the XSCF Unit is redundantly configured, it may be
necessary to switch the active side over to the standby side.
The procedure for switching the XSCF Unit status from standby to active is as follows:
■ Command operation
1. Log in the XSCF Unit on the standby side.
2. Use the switchscf(8) command to switch the XSCF Unit from standby status to
active status.
Note – If possible, confirm that the ACTIVE LED states changes on the front panels of
both XSCF Units. Execute the switchscf(8) command only on one side (active side or
standby side) of the XSCF Units to automatically switch active/standby status of the other
XSCF Unit.
For specifying an option in the switchscf(8) command, see the XSCF Reference Manual.
Processing Continued at XSCF Reset or Failover
In case an XSCF reset or failover was generated while the following processes are executing,
the process will be continued:
■ Domain power-on process
■ Domain power-off process
■ DR function