Chapter 8 Upgrade of XSCF Firmware and Maintenance 8-25
Note – The table is read in the same way as TABLE 8-3. For examples of logs, see
Appendix B.
Note – When the log becomes full, the log data is overwritten, beginning with the oldest
log.
8.2.2 Method of Collecting the Log Information
The field engineers and authorized service personnel collect the log information. Also, the
system administrator might collect the log information.
To download the log information, execute the snapshot(8) command with some options in
the XSCF Shell. When the command is executed, all XSCF log information is saved at the
specified location.
Note – The download information by using the snapshot(8) command does not include
log archives. The archived logs are stored on the archive host. The log archives can be
accessed by logging in to the archive host.
The log can be saved in the device using one of the following two methods.
The configuration information can be saved and restored when a USB device has been
connected to the USB connector mounted on the XSCF Unit front panel of the
M4000/M5000/M8000/M9000 servers or on the rear panel of the M3000 server.
The log data is transmitted through the network with an encryption protocol.
Note – The USB device should only be formatted using the FAT32 file system. Please ask
authorized service personnel about the USB capacity and the handling of USB devices.
Note – The snapshot(8) command can encrypt collected data by specifying an option. If
you collect the data, be sure to ask the authorized service personnel to collect only the log
file, the encryption information, and the method of sending the log file.